Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Res Int ; 2018: 7918781, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30627572

RESUMO

OBJECTIVE: Previous studies have shown the effect of amalgam removal on the healing of oral lichenoid lesions (OLLs); however, no specific replacement materials have been suggested. The present series evaluated long-term results following the complete replacement of amalgam restorations with feldspathic ceramic inlay-onlay restorations for a group of patients with OLLs whose lesions were suspected to be related to amalgam restorations. MATERIALS AND METHODS: Twenty-four patients who had OLLs suspected to be related to their amalgam restorations were initially recruited. The patients underwent patch tests for a series of dental materials, in addition to clinical and histopathological examination. Sixteen (67%) of the 24 patients had their amalgam replaced with feldspathic ceramic inlay-onlay restorations and were examined within a follow-up period of 3 months to 5 years. RESULTS: After 3 months of clinical follow-up, complete healing (63%) was noted in all patients with OLLs whose lesions were in only close contact with their amalgam restorations. Healing was significantly related to the combination of lesions with close contact with the amalgam restoration and a diagnosis of OLL (x2 test, P=0.02). CONCLUSION: Feldspathic ceramic can be safely used as a replacement material for patients with OLLs to diminish adverse reactions to amalgam restorations.


Assuntos
Amálgama Dentário , Reparação de Restauração Dentária , Restaurações Intracoronárias , Líquen Plano Bucal/terapia , Cicatrização , Adulto , Idoso , Feminino , Seguimentos , Humanos , Líquen Plano Bucal/etiologia , Líquen Plano Bucal/patologia , Masculino , Pessoa de Meia-Idade , Mucosa Bucal/metabolismo , Mucosa Bucal/patologia
2.
Biomed Res Int ; 2017: 8652720, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29238725

RESUMO

PURPOSE: Friction-style and spring-style torque wrenches are used to tighten implant abutments and prosthetic screws. The mechanical stability of these torque wrenches is crucial for the implant-abutment connection. The purposes of this study were to assess the performance of five brands (Straumann, Zimmer, Implant KA, Bredent, and Biohorizons) of wrench and to evaluate possible changes in applied torque values of aged wrenches. MATERIALS AND METHODS: Five new and aged wrenches that had been used approximately 250 times in a 1-year period were tested. The torque applied by friction- and spring-style wrenches was measured with a specially designed strain gauge indicator. Descriptive statistics, the one-sample t-test, and the independent-samples t-test were used to analyze values obtained from all torque wrenches. RESULTS: The accuracy of new and aged torque devices of all brands except Bredent differed significantly from the target values, but the mean values for aged and new wrenches did not differ significantly from each other (p > 0.05). Values for the spring- and friction-type torque wrenches deviated from the target values by 11.6% and 10.2%, respectively. CONCLUSION: The accuracy of aged torque wrenches is adequate for prosthetic screw tightening, but that of new torque wrenches is unsatisfactory and must be examined carefully before delivery.


Assuntos
Parafusos Ósseos/normas , Implantação Dentária Endóssea/instrumentação , Implantes Dentários/normas , Análise do Estresse Dentário , Humanos , Estresse Mecânico , Torque
3.
Biomed Res Int ; 2017: 7376261, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28473988

RESUMO

Preload is applied to screws manually or using a torque wrench in dental implant systems, and the preload applied must be appropriate for the purpose. The aim of this study was to assess screw loosening and bending/torsional moments applied by clinicians of various specialties following application of manual tightening torque to combinations of implants and abutments. Ten-millimeter implants of 3.7 and 4.1 mm diameters and standard or solid abutments were used. Each group contained five implant-abutment combinations. The control and experimental groups comprised 20 and 160 specimens, respectively. Implants in the experimental group were tightened by dentists of different specialties. Torsional and bending moments during tightening were measured using a strain gauge. Control group and implants with preload values close to the ideal preload were subjected to a dynamic loading test at 150 N, 15 Hz, and 85,000 cycles. The implants that deformed in this test were examined using an optical microscope to assess deformities. Manual tightening did not yield the manufacturer-recommended preload values. Dynamic loading testing suggested early screw loosening/fracture in samples with insufficient preload.


Assuntos
Dente Suporte , Implantes Dentários/normas , Análise do Estresse Dentário , Estresse Mecânico , Parafusos Ósseos , Materiais Dentários/química , Planejamento de Prótese Dentária , Humanos , Torque
4.
J Istanb Univ Fac Dent ; 49(1): 10-18, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-28955520

RESUMO

PURPOSE: The aim of this study was to evaluate the effect of thickness of zirconia on curing efficiency of resin cements. MATERIALS AND METHODS: Four discs with 4.0 mm in diameter were prepared from non-HIP translucent zirconia blocks using a CAD/CAM system and feldspathic ceramic was layered onto discs. Thus, 4 ceramic disc samples were fabricated: (G) 0.5 mm zirconia- as a control group, (G1) 0.5 mm zirconia and 0.5 mm feldspathic, (G2) 1.0 mm zirconia and 0.5 mm feldspathic and (G3) 2.0 mm zirconia and 0.5 mm feldspathic ceramic layer. 2 different dual cure cements were polymerized using a LED curing unit. Degree of conversion was evaluated using Vickers Hardness Test and depths of cure of samples were measured. Data were analyzed statistically using One-way ANOVA and Tukey's HSD test (p<0.05). RESULTS: Microhardness and depth of cure values were different under same thickness of ceramic discs for two resin cements. As the thickness of the zirconia discs increased, the microhardness values and depth of cure decreased. CONCLUSION: Photocuring time cannot be the same for all clinical conditions, under thicker zirconia restorations (>2.0 mm), an extended period of light curing or a light unit with a high irradiance should be used.

5.
J Istanb Univ Fac Dent ; 49(2): 8-16, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-28955530

RESUMO

PURPOSE: Adequate polymerization is a crucial factor in obtaining optimal physical properties and a satisfying clinical performance from composite resin materials. The aim of this study was to evaluate the polymerization efficiency of dual-cure resin cement cured with two different light curing units under zirconia structures having differing thicknesses. MATERIALS AND METHODS: 4 zirconia discs framework in 4 mm diameter and in 0.5 mm, 1 mm and 1.5 mm thickness were prepared using computer-aided design system. One of the 0.5 mm-thick substructures was left as mono-layered whereas others were layered with feldspathic porcelain of same thickness and ceramic samples with 4 different thicknesses (0.5, 1, 1.5 and 2.0 mm) were prepared. For each group (n=12) resin cement was light cured in polytetrafluoroethylene molds using Light Emitting Diode (LED) or Quartz-Tungsten Halogen (QHT) light curing units under each of 4 zirconia based discs (n=96). The values of depth of cure (in mm) and the Vickers Hardness Number values (VHN) were evaluated for each specimen. RESULTS: The use of LED curing unit produced a greater depth of cure compared to QTH under ceramic discs with 0.5 and 1 mm thickness (p<0.05).At 100µm and 300 µm depth, the LED unit produced significantly greater VHN values compared to the QTH unit (p<0.05). At 500 µm depth, the difference between the VHN values of LED and QTH groups were not statistically significant. CONCLUSION: Light curing may not result in adequate resin cement polymerization under thick zirconia structures. LED light sources should be preferred over QTH for curing dual-cure resin cements, especially for those under thicker zirconia restorations.

6.
Dent Mater J ; 33(3): 368-72, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24882110

RESUMO

Miniplates have been used during the last decade to facilitate stability between bony fragments in the maxillofacial region and are currently the preferred surgical method for the fixation of fractures and osteotomies. The aim of this study was to evaluate and compare the biomechanical behaviors of six different types of miniplates used to reconstruct mandibular body fractures: Group 1 (straight, 2 holes, 12.0 mm spacing), Group 2 (straight, 4 holes, 9.0 spacing), Group 3 (straight, 6 holes, 9.0 mm spacing), Group 4 (L-shaped, 4 holes, 9.0 mm spacing, right hand plate), Group 5 (Y-shaped, 5 holes, 12.0 mm spacing), and Group 6 (double Y-shaped, 6 holes, 9.0 mm spacing). Thirty bovine hemimandibles and a custom-made 3-point biomechanical test frame mounted on a Shimadzu universal test machine were used to evaluate the six different miniplate systems. Results revealed that Group 1 (straight, 2 holes, 12.0 mm spacing) and Group 4 (9.0 mm spacing, right hand plate) had the lowest biomechanical stability, whereas Group 6 (6 holes, 9.0 mm spacing) had the highest biomechanical stability. Group 6 also provided statistically greater resistance to displacement than Group 1 and Group 4.


Assuntos
Mandíbula/cirurgia , Animais , Fenômenos Biomecânicos , Bovinos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...